Fluke-1507, 1503 절연저항 미터 |
절연저항 테스터기 |
FLUKE 1503/1507 절연테스터는 1000V(가변) 테스트 레인지를 |
가진 절연저항계 입니다. 전기설비, 전동기, 발전기, 케이블 등의 |
절연 테스트, 수리, 점검 어플리케이션에 적합한 테스트 장비 입니다. |
AC/DC Voltage Measurement | ||
Accuracy |
Range |
600.0 V |
Resolution |
0.1 V | |
50 Hz to 400 Hz ± (% of Rdg + Digits) |
± (2 % + 3) | |
Input impedance |
3 MΩ (nominal), < 100 pF | |
Common mode rejection ratio (1 kΩ unbalanced): |
> 60 dB at dc, 50 or 60 Hz | |
Overload Protection |
600 V rms or dc | |
| ||
Earth bond resistance measurement | ||
Range/Resolution |
20.00 Ω |
0.01 Ω |
200.0 Ω |
0.1 Ω | |
2000 Ω |
1.0 Ω | |
20.00 kΩ |
0.01 kΩ | |
Accuracy |
± (1.5 % + 3) | |
Overload Protection |
2 V rms or dc | |
Open Circuit Test Voltage |
> 4.0 V, < 8 V | |
Short circuit current |
> 200.0 mA | |
| ||
| ||
Earth bond resistance measurement | ||
Range/Resolution |
20.00 Ω |
0.01 Ω |
200.0 Ω |
0.1 Ω | |
2000 Ω |
1.0 Ω | |
20.00 kΩ |
0.01 kΩ | |
Accuracy |
|
± (1.5 % + 3) |
Overload Protection |
|
2 V rms or dc |
Open Circuit Test Voltage |
|
> 4.0 V, < 8 V |
Short circuit current |
|
> 200.0 mA |
| ||
General Specifications | ||
Maximum voltage applied to any terminal: |
600 V ac rms or dc | |
Storage Temperature |
-40 °C to 60 °C (-40 °F to 140 °F) | |
Operating Temperature |
-20 °C to 55 °C (-4 °F to 131 °F) | |
Temperature Coefficient |
0.05 x (specified accuracy) per °C for temperatures < 18 °C or > 28 °C (< 64 °F or > 82 °F) | |
Relative Humidity |
0 % to 95 % @ 10 °C to 30 °C (50 °F to 86 °F) | |
0 % to 75 % @ 30 °C to 40 °C (86 °F to 104 °F) | ||
0 % to 40 % @ 40 °C to 55 °C (104 °F to 131 °F) | ||
Vibration |
Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument | |
Shock |
1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor) | |
Electromagnetic compatibility: |
In an RF field of 3 V/M, accuracy = specified accuracy (EN 61326-1:1997) | |
Safety |
Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV) | |
Certifications: |
CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard IEC/EN 61010-1 2nd Edition | |
Batteries |
Four AA batteries (NEDA 15A or IEC LR6) | |
Battery Life |
Insulation test use: |
Tester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off. |
Resistance measurements: |
Tester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off. | |
Size |
5.0 cm H x 10.0 cm W x 20.3 cm L (1.97 in H x 3.94 in W x 8.00 in L) | |
Weight |
550 g (1.2 lb) | |
IP Rating |
IP40 | |
Altitude |
Operating: |
2000 m CAT IV 600 V, 3000 m CAT III 600 V |
Non-operating (storage): |
12,000 m | |
Over-range capability: |
110 % of range | |
Included accessories: |
TL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe |